AR# 71378

LogiCORE Sensor Demosaic v1.0 - Why does changing the Bayer Phase (0x0020) have no impact on the output?

描述

Changing the value of the Bayer Phase (register 0x0020) has no impact on the output image when using the Sensor Demosaic v1.0.

This is the case in both simulation and hardware.

How can I change the Bayer Phase configuration?

解决方案

The address corresponding to the Bayer Phase setting mentioned in (PG286) the LogiCORE Sensor Demosaic Product Guide is incorrect.

The correct address is 0x0028.

This will be updated in a future version of the product guide.

链接问答记录

主要问答记录

Answer Number 问答标题 问题版本 已解决问题的版本
68769 LogiCORE Sensor Demosaic - Release Notes and Known Issues for the Vivado 2017.3 tool and later versions N/A N/A
AR# 71378
日期 06/05/2019
状态 Active
Type 已知问题
Tools
IP